Faqs & Tips

Registers & Grilles
Venting & Flexible Duct
Galvanized Duct, Pipe & Fittings

FAQS

TIPS

How are floor and ceiling registers used?

How are floor and ceiling registers used?

Floor registers are part of your heating and ventilation system. They give you an important way to regulate airflow within your home.

Here are some of the ways Imperial Floor Registers can add comfort to your home:
  • Maintain uniform temperatures from room to room
  • Direct air flow away from certain areas
  • Isolate rooms that you don’t need to heat or cool
  • Block cold air from entering the home from the basement
  • Help circulate cold air from the basement to cool the home
  • Move warm air produced by a wood stove to the upper floors

What is the difference between a register and a grille?

What is a register?

Registers are covers or grates placed in the air flow openings in your house. They give you control over volume and direction of the air entering a room. A floor register works by pressing the lever on the floor register's damper box to open shutters that direct air into the room. By pressing the lever on the floor register's damper box the other way, the shutters close reducing the flow of air.

Characteristics of registers
  • They include a damper that provides control, to direct and diffuse the amount of air that enters a room.
  • Registers may direct air in one, two, three or four different directions depending on the type of register.
  • They are installed on floors, walls and ceilings.
  • If they are blocked the temperature in a room can be greatly affected.
  • Most registers have a single valve or a multi-shutter damper.

What is a grille?

Grilles are the vents through which air is pulled out of a room for circulation back to the central heating or cooling unit. Grilles do not have the damper controls found on registers. Imperial Grilles are installed in cold air return ducts.

Characteristics of grilles
  • They have no damper to close off the flow of air.
  • They may be located in floors, ceilings and walls.
  • They provide return air circulation within a room; where unobstructed flow is required for heating/cooling system efficiency.
  • You may have several small grilles located throughout your home or one large central grille installed near the furnace.

Troubleshooting: find solutions to common dryer venting problems

If you have one or more of these problems:

  • My laundry room seems hotter and more humid than usual.
  • My clothes take an unusually long time to dry.
  • My clothes are hotter than usual at the end of a drying cycle.
  • The damper on my outside exhaust vent hood does not open fully when the dryer is operating.
  • The outside of my dryer seems unusually hot.

Actions to take
  • Unplug the dryer, if you have a gas dryer, shut off the gas.
  • Inspect your duct system for air leaking, blockage and/or damage.
  • Inspect your vent hood from the exterior of your home for damage or blockage.
Possible solutions
  • Clean the dryer vent pipe of lint and debris. Most of the lint or debris built-up will be at the end of the duct connections. Imperial brushes can be used to clean these areas.
  • If the duct system or vent hood is damaged, replace them.
  • If the connections are loose, adjust them.
  • If your problem has not been solved, get your dryer checked by a professional
How to replace an existing register or grille

How to replace an existing register or grille

When installing new floors, many overlook replacing existing floor registers with ones that complement their new flooring and home decor. Fortunately, this is something anyone can do themselves.

Step-by-step

  1. Determine the size of the register.
    Remove the original vent cover to expose the ventilation opening. Measure the length and width of the opening. Subtract 1/8" to 1/4"(depending on how square the opening is) and this is the inside dimensions for the new floor registers. Reinstall old register until you get the new ones.
  2. Select an Imperial Register.
    Imperial Registers are designed to fit the standard openings used in most homes. A wide variety of designs and finishes are available.
  3. Unpack and Install.
    Imperial Registers come fully assembled. Simply drop into place.

To replace a ceiling register

Replacing a ceiling register is just like that of the floor register except for a couple of steps:

  1. After the initial size check, make sure that there is sufficient wall or ceiling space at the short ends of the wall register to allow for you to attach it to the wall with screws that are provided with your new register.
  2. Final installation requires a screwdriver to attach the wall register to the wall or ceiling with the screws provided

Measure the opening…NOT the register!

How to create an new opening for a register or grille?

How to create an new opening for a register or grille?

If you are expanding your heating and/or cooling system, we recommend you consult an HVAC technician about placement and installation.

If you are simply adding a register, say for distributing heat from a wood stove, following these instructions should help:

What you'll need:
  • Heating duct
  • Tape measure
  • Pencil
  • Saw
  • Imperial Register or Grille
Step 1 - Locating and measuring

Measure the rough opening as specified on the Imperial Register or Grille packaging. Check for joists and other potential obstructions before locating the register or grille. When you’re doing this, you need to be sure that it sits square and an ample distance from the wall. Draw the shape of the opening on the existing floor.

Step 2 - Sawing

Next, saw through the subfloor and the hardwood floor in your room. If you’re putting carpet in the room, you will need to fit the floor heating vents before you install the carpet. Using a reciprocal saw, cut through the floor and cut roughly around the rectangle you’ve made where the floor heating vent will fit through the floor. You don’t have to be exact with this because the frame of the Imperial Grille will cover any irregularities.

Step 3- Fitting the vent

An Imperial Floor Register or Vent uses its own weight to stay in place on the floor, so just insert into opening

How to deflect air where you want it

Since hot air rises, you might want to direct it to the center of a room

The Imperial Pop-Up Register is perfect for floor registers that are covered by curtains or furniture. When not covered, it works like a typical floor register. But when the curtains are closed and cover the register, simply close the register top, and pop it up to redirect the airflow to the side, for optimum heating or cooling efficiency!

Imperial Pop-Up Registers also features a 100% shut off damper that stops the airflow completely, a handy feature for total control over airflow or when airflow is not required.

The Imperial Pop-Up register is easy to clean, rust proof, scratch resistant and ideal for light humidity areas. It can be installed in both floor and ceiling application with heating and cooling systems.

The Imperial Air Deflector is also an alternative.

This is one of the easiest and inexpensive home improvements you can make

This is one of the easiest and inexpensive home improvements you can make

When it comes to decorating, one area of the home that is often overlooked or passed over are heat registers.

These vent coverings are easy to forget about, as they can seem like such a basic part of your home. The floor registers and grilles that originally came with your home have probably seen better days. Using decorative registers in your home can really help improve the overall look of your new or current room design.

If you are installing a new floor, you should add an attractive finishing touch with new registers and/or grilles. Imperial Floor Registers add style, class, richness, quality, originality, and high value to any home. They come in a variety of materials, finishes and styles for a perfect match or distinctive detail.

Floor registers give you added control over air circulation and protect you, your kids, and your pets from any harm from open-air ducts.

Imperial offers a broad selection of registers

Imperial offers a broad selection of registers

  • Decorative Imperial Floor Registers come in a variety of materials, finishes and styles to fit perfectly with traditional, modern and elegant décor.
  • For something with a warmer or homier touch, consider Imperial natural wood registers available in light, pre-finished oak or unfinished where you can stain yourself.
  • Imperial registers designs range from very basic slotted openings to elaborate patterns and designs.
  • Pick colors or finishes to match each room of the house

Selection Tips

Selection Tips

  • Use Imperial Floor Registers to accent a room with a style and finish that matches the scheme of that room.
  • Rooms with carpeting will use a different floor register that a room that has wood floors such as typical dining room and kitchen areas. By choosing a decorative register to match that specific type of flooring, you will achieve the best overall look for the room.
  • If you have hardwood flooring in a certain room of your home that has been stained with an unknown color, simply get an unfinished wood floor register and have someone match a stain to your floor.
  • Match the floor register to other items in the room like cabinets, shelving and wallpaper.
  • Match ceiling and wall grilles to blend with the room’s new look.
  • In most cases, a straightforward design with blended accessories will give the most practical look that you and the rest of your family can live with for years to come.

Clothes dryer performance

Planning points for you dryer venting system

  • When planning a new dryer vent system, always select the route that will provide the straightest and most direct path outdoors.
  • Plan the installation to use the fewest number of elbows and turns.
  • Elbows allow the dryer to sit close to the wall without kinking and/or crushing the transition duct.
  • The male (crimped) end of each section of rigid metal or flexible metal (semi-rigid) ducting must point away from the dryer.
  • Rigid metal duct joints should be made air and moisture tight by wrapping the overlapped joints with duct tape or aluminum tape.
  • Duct that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint buildup.

Universal Pest GuardLouvered Vent Hood
with Plastic Guard
Preferred Vent Hood with Removable Guard
  • Installs over any style of
    3" or 4" dryer or bathroom
    fan exhaust vent
  • Hinged access guard for
    easy cleaning

Dryer installation applications

Tips on duct installation

Prior to installing a duct system, you should

  • Sketch out your layout.
  • Make a checklist of the duct, pipe and fittings needed to complete your installation.
  • Estimate the type of joints required.
  • Consult your store representative for assistance.
  • Check local building codes in your area before planning your installation.

About airflow

It is important to maintain a neutral pressure in the home by having balanced airflows between the supply and return system.

  • Airflow can be restricted by certain fittings and too many turns in a system.
  • Dampers allow for adjustments of air distribution.
  • Reducers can also balance your system.
  • Use the correct pipe size for your system.
    A too large or too small fitting can hamper airflow.

Branching

The total amount of air that your furnace or air conditioning system can move stays the same even if you add a branch.
Whenever you branch, you must reduce the size of the pipe to maintain air velocity.

  • For each branch of ductwork, determine your start point and your end point.
  • The new supply line should always be drawing off a main air supply duct.
  • Use a take-offwhen your start point is a rectangular main duct.
  • Use a teeor wyewhen your start point is a round main duct.
    Tees split, but do not reduce, and an appropriate reducer must be added.
  • Use a boot when your end point is at a room floor, wall or ceiling.
  • Use elbows to make any necessary turns between the start point and end point.
    90º round adjustable elbow can be adjusted to make any angle from 0º through 90º.

A few more tips

  • Sheet metal ducts must be insulated when located in an unconditioned space.
  • Try to avoid cutting by using full lengths of pipe.
  • Crimps must be placed so that the airflow exits at the crimped end.
  • Never locate ducts at the end of the trunk line run.
    The last take-off run should be located 12" - 18" from end.
  • Always stagger take-off ducts by 12" to maintain pressure.
  • When connecting ducts, cut an accurate hole; fasten components mechanically with at least one screw per side and seal leaks using a high-grade tape or preferably mastic.
  • It is recommended that all register boxes be sealed to the drywall or floor with caulking or mastic.

Some tools and materials you may need

Terms and definitions you need to know

Terms

Basement system

The main duct that comes out of the plenum is rectangular. Air is directed up into the living area

Branch duct

Smaller sections of pipe that carry air from the main duct to individual rooms.

Ceiling system

The main duct that comes out of the plenum is round. Air is directed down into the living area.

Crimper

Tool shaped like a pair of pliers, which is used to make corrugations in the end of a sheet metal duct to reduce its size.

Forced air system

A system of heating or air-conditioning in which the air is forced through a chamber connected to distributing ducts.

Main duct

A large duct that comes directly out of the furnace or central air source or plenum. It is sometimes called a trunk duct.

Plenum

HVAC system accumulation and distribution chamber for connection of ducts.

Return duct

The central heating or cooling system contains a fan that gets its air supply through the return ducts. These ducts should ideally be installed in every room of the house.

Stack duct

A rectangular duct that is used between wall studs to vent supply and return duct runs.

Supply duct

The ductwork that carries air from the air handler to the rooms in the house.

Oval duct compared to round duct

Oval duct provides a more efficient alternative to rectangular duct in application where round can't be used. It is manufactured with the same techniques used to make round duct. As a result, oval duct shares many of the performance characteristics of round duct.

Do's & Don'ts about ducts

Do's & Don'ts about ducts

Do's
  1. To reduce the risk of fire, the dryer MUST BE EXHAUSTED OUTDOORS.
  2. Use only 4" rigid metal or UL-Listed flexible metal (foil-type or semi-rigid) ducting to connect the dryer to the home exhaust system.
  3. For best drying performance, rigid metal transition duct is recommended.
  4. If rigid metal duct cannot be used, UL-Listed flexible metal (semi-rigid) duct should be used.
  5. UL-Listed flexible metal (foil-type) duct should be used only in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used.
  6. Flexible metal (foil-type) duct must be fully extended with excess duct removed to avoid sagging and kinking.
  7. Flexible metal (foil-type or semi-rigid) ducting is acceptable only if they are accessible for cleaning.
  8. Total length of UL-Listed flexible metal (foil-type or semi-rigid) ducting cannot exceed 8’.
Don'ts
  1. Never install UL-Listed flexible metal (foil-type or semi-rigid) duct in walls, ceilings, floors or other enclosed spaces.
  2. Do not assemble duct using duct tape, screws or other fastening devices that extend into the interior of the duct. These fasteners can accumulate lint, creating a potential fire hazard.
  3. Do not use duct longer than required. Longer duct systems can accumulate lint, creating a potential fire hazard.
  4. Do not crush, kink or collapse duct.
  5. Avoid resting the duct on sharp objects.
Do's & Don'ts about dryer exhaust

Do's & Don'ts about dryer exhaust

Do's
  1. Exhaust vent hood must be installed at least 12" from the ground or any object that may be in the path of the exhaust air.
  2. Use caulking compound to seal exterior wall opening around exhaust vent hood.
  3. The exhaust vent hood should cap the vent system to prevent rodents and insects from entering the home.
  4. Before connecting replacement duct to the exhaust outlet of an existing dryer, make sure the exhaust port is clean and the exhaust vent hood is not plugged with lint.
  5. Provide an access to the exhaust system, especially at turns and joints, so system can be inspected and cleaned at least once a year.
  6. Observe all governing codes and ordinances.
Don'ts
  1. Do not terminate dryer exhaust in a chimney, a wall, a ceiling, gas vent, crawl space, attic, under an enclosed floor, or in any other concealed space of a building.
  2. Never terminate the dryer exhaust into a common duct with a kitchen exhaust system. A combination of grease and lint creates a potential fire hazard.
Floor Register Size Selection Guide

Floor Register Size Selection Guide