Modèle RD-4MC
Modèle RD-4MC

How it works

Relative humidity sensor dial

OFF / 60% / COMFORT ZONE / 30%

Overrides the ventilation system to high speed once the level of humidity is above the set point.

If the wall control is in CONT or INTERM mode the ventilation system will automatically return to its original mode once the level of humidity is below the set point.

Speed control selector

(Ventilation speed)

OFF – Sends command to shut down ventilation system.

NORMAL – The ventilation system operates on installers set speeds (CONT and OVERRIDE).

REDUCE – The ventilation system operates at 30% reduction in CONT and OVERRIDE speed.

Note: REDUCE mode will not decrease below the maximum low speed of the ventilation system.

Mode control selector

INTERM – Ventilation is halted meaning,automatically stopping and starting at intervals the ventilation system from a command from a remote wall controls.

CONT – Provides a continuous ventilation rate. The ventilation system will increase to high from command of remote wall controls.(Recommended for maximum indoor air quality.)

RECIRC – The recirculation mode recycles already-heated ambient air from a selected area and distributes throughout your home. This enables the ventilation system to have an auxiliary air supply automatically during defrost sequence or when RECIRC mode is selected.

Cycles per hour selector

0 – The ventilation system operates at the settings of your RD Series wall control.

20/40 – The ventilation system cycles automatically for 20 minutes at high speed and returns to previous settings (CONT, INTERM or RECIRC, pending settings on the mode selector switch or your RD series wall control.)

30/30 – The ventilation system cycles automatically for 30 minutes at high speed and returns to previous settings (CONT, INTERM or RECIRC, pending settings on the mode selector switch or your RD series wall control.)

Note: The ventilation system will go to high speed if a demand from any remote wall control is activated when in the 2nd stage of cycle. Ex: 40 or 30 minutes.

Mode indicator

Orange light = ON (CONT / INTERM)

Green LED light = Override

 

Maintenance reminder indicator

Light is on when HRV ERV needs to be maintain.

Light is on after 90 days consecutive power to the ventilation system.

To reset the maintenance LED reminder, put the range selector switch to the OFF position.

TIPS: You can also opt to put your ventilation system on INTERM or OFF mode during the warmer months and run it only at night time once the temperature cools down.

Features

Relative Humidity Sensor Dial
Off, 60%, Comfort Zone, 30%

Speed Control Selector
Off, Normal, Reduced

Mode Control Selector
Intermittent, Recirculation & Continuous Ventilation

Cycles Per Hour Selector
0/0, 20/40, 30/30

Mode Indicator 
Orange light - Power
Green light - Override

Maintenance Reminder Indicator 
Orange light - Power
Green light - Override
 


Compatibility

The RD-4D model™ is compatible with the DH and SS 3.12DD series.
 


Dimensions

()
+
-
Contrôles muraux
• Évent Matrix
• Commandez des filtres
• Grilles de circulation d'air
Téléchargements
Guide de l'utilisateur Guide de l'utilisateur 2.18 Mo
Installation Guide Wall Controls (English/Français) Installation Guide Wall Controls (English/Français) 1.67 Mo
Achetez vos filtres ICI!
Foire aux questions
Produits certifiés et/ou fier membre de ces associations
Imperial Group
Siège / Service à la clientèle
1.800.561.3100
Restez
connecté
Accueil
Compagnie
Possibilités
Contactez-nous
Plan du site
Support
Prix et distinctions
Au sein de la communauté
Quoi de neuf?
Prochaines activités
Grilles et registres
Ventilation et conduits flexibles
Poêles
Foyers
Greentek
Imperial Air Technologies
Rampes, colonnes, clôtures
Produits galvanisés
Produits de construction
Filtration de l'air
© 2017 Imperial Manufacturing Group|tous droits réservés|Un solution NuFocus Online
Content Support
E-mail Now